XRF
X-Ray Thickness Measurement
XRF assesses thickness non-destructively on suitable coating-substrate systems. Separating layers in multilayer systems depends on element combination, thickness, geometry and the calibration model.
What it tells youShows whether the target thickness was met and how it is distributed across the part.

Micro-Vickers Hardness
A pyramid indenter applies a controlled load and hardness is calculated from the size of the indentation. Micro loads are used on thin coatings.
What it tells youShows whether wear-resistant coatings such as hard gold, hard silver and nickel-phosphorus reach the target hardness.

Stereo Microscope Inspection
The part surface is inspected before and after plating for scratches, residues, signs of porosity, stains and visual continuity.
What it tells youBefore/after comparison helps tell visible defects apart. It does not give quantitative thickness uniformity or porosity.

Cross-Cut Adhesion Test
A grid is cut into the coating and tape is pulled to see whether the layer separates from the substrate.
What it tells youGives a qualitative indication of separation only on suitable systems and with a defined method. A pass does not prove the whole pre-treatment chain.

Bend Test
A plated sample is bent to a defined angle and the bend zone is checked for cracking, flaking or peeling.
What it tells youGives a qualitative indication under defined bending; it does not on its own prove fitness for service.

Salt Spray (Corrosion) Test
The sample is held in a controlled salt fog for a set time and the onset and spread of corrosion are assessed.
What it tells youShows how the coating system behaves under humidity and salt exposure in defence, aerospace and outdoor use. Duration and acceptance criteria are defined per project.